Report date: Mar 18, 2021
10. Adequate handwashing sinks properly supplied and accessible
- comments: observed no handwashing signs at hand washing sinks in rear prep and washroom areas. Instructed manager to provide.
21. Proper hot holding temperatures
- comments: observed chicken (109. 6f-123. 5f)stored at improper
temperature in hot holding unit. Instructed manager to discard approximately 50lbs and $100 of cooked chicken. All hot tcs food must maintain 135f or above during storage, preparation, display and service. Priority 7-38-005 citation issued
22. Proper cold holding temperatures
- comments: observed the following cold tcs foods stored at improper temperature in walk-in cooler: salmon 45. 3f, catfish 46. 2f-48. 5f, curry chicken 48. 5f, tilapian 48. 5f, lamb chops 48. 5f, turkey legs 48. 5f, lobster tails 49. 6f. Instructed manager to discard approximately 100lbs and $854 of product. All cold tcs food must maintain 41f or below during storage, preparation, display and service. Priority 7-38-005 citation issued
33. Proper cooling methods used; adequate equipment for temperature control
- comments: observed walk-in cooler not maintaining proper temperature 50. 2f. Instructed manager to repair. Walk-in cooler must maintain 41f or below. Walk-in cooler is tagged held for inspection and must not be used until reinspected by chicago department of public health. Priority 7-38-005 citation issued
37. Food properly labeled; original container
- comments: observed bulk containers not labeled in rear prep/storage area. Instructed manager to label all bulk containers with common name of food.
39. Contamination prevented during food preparation, storage & display
- comments: observed food items stored on floor in front counter(bread and jerk sauce), prep(chicken and fish) and storage areas. Instructed manager to elevate all food items six inches off floor.
45. Single-use/single-service articles: properly stored & used
- comments: observed single service articles not inverted. Instructed manager to invert all single service articles to protect from contamination.
47. Food & non-food contact surfaces cleanable, properly designed, constructed & used
- comments: observed damaged and missing gaskets on doors of walk-in and reach-in coolers. Instructed manager to replace and maintain.
48. Warewashing facilities: installed, maintained & used; test strips
- comments: observed no chemical test kit available. Instructed manager to provide test kit for proper concentration in sanitizing solutions. Priority foundation 7-38-005 citation issued.
49. Non-food/food contact surfaces clean
- comments: observed food debris and grease buildup on interior and exterior surfaces of cooking equipment, prep tables, shelving units, coolers, and freezers. Instructed manager to clean and maintain.
51. Plumbing installed; proper backflow devices
- comments: observed leaking drainpipe under 3-compartment sink. Instructed manager to repair and maintain.
53. Toilet facilities: properly constructed, supplied, & cleaned
- comments: observed no self-closing device on men washroom door. Instructed manager to provide.
55. Physical facilities installed, maintained & clean
- comments: observed dust buildup and soot on ceiling tiles, ceiling vents, and light shields in prep area. Instructed manager to clean and maintain.
56. Adequate ventilation & lighting; designated areas used
- comments: observed no light in women washroom. Instructed manager to provide adequate lighting and maintain.
56. Adequate ventilation & lighting; designated areas used
- comments: observed no light shield in walk-in cooler. Instructed manager to replace and maintain.
Source: